{"product_id":"dentsply-integrity-temporary-crown-and-bridge-material","title":"Dentsply Integrity Temporary Crown And Bridge Material","description":"\u003cp\u003e\u003cstrong\u003eDentsply Integrity Temporary Crown and Bridge Material with\u003c\/strong\u003e\u003cspan\u003e Fluorescence is a two-component material designed for creating temporary crowns and bridges. It is an automixed material that consists of multi-functional methacrylic esters. This versatile material can be used for both short-term and long-term temporary restorations. The Integrity Temporary Crown \u0026amp; Bridge Material with Fluorescence offers several benefits. It allows for the fabrication of temporaries that are not only fast and strong but also aesthetically pleasing. The material has a consistent texture with minimal shrinkage, enabling easy handling and reducing the need for adjustments. This feature saves valuable time for dental professionals. The packaging of Integrity Temporary Crown and Bridge Material in a cartridge format serves to simplify delivery and minimize product waste. The indications for using this material include the direct fabrication of temporary restorations such as veneers, inlays, onlays, crowns, and bridges. These temporaries are typically employed in indirect restorative procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003ePerfect mix ratio with no cross contamination\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eLess than 5° C temperature change in the mouth during setting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eDoes not damage the pulp and offers great patient comfort\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eBonds to itself for easy repair\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003ePolishes to a natural luster for superb results\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eGreat consistency for easy handling and cleanup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eGreat esthetics\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmediately before each use\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Bleed cartridge prior to inserting new mix tip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0-5 seconds\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- Material dispensed into preliminary impression\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-45 seconds -\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eMaterial inserted into the mouth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-3 minutes -\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eRemoval from mouth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 minutes -\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eRemove the O2-inhibited layer and begin to trim the excess with-rotary instruments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7 minutes -\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eComplete contours and polish\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eComposition  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBarium glass\u003c\/li\u003e\n\u003cli\u003eFumed Silica\u003c\/li\u003e\n\u003cli\u003eMethacrylate Monomers\u003c\/li\u003e\n\u003cli\u003eCatalyst\u003c\/li\u003e\n\u003cli\u003eStabilizers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1x 76gm Cartridge\u003c\/li\u003e\n\u003cli\u003e15 x Small Mixing Tips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDirection To Use: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRaise the release lever vertically upward, while simultaneously pulling the plunger all the wayback in the dispenser handle.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCartridge Loading :\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOpen cartridge lock by lifting up top clasp.\u003c\/li\u003e\n\u003cli\u003eOrient and insert cartridge with notch facing down.\u003c\/li\u003e\n\u003cli\u003eClose the top clasp to lock cartridge into dispenser gun.\u003c\/li\u003e\n\u003cli\u003eRemove the cartridge cap by turning 90° counterclockwise. Discard the cartridge cap.\u003c\/li\u003e\n\u003cli\u003eThe used mixing tip can be disinfected and left in place until the next use to serve as a self-sealing cap.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDispensing :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDispense and discard a “pea” size amount of base and catalyst before installing mix tip to ensure even flow from cartridge. Use gentle pressure. Be sure no plug is present. If any plug blocks flow, clear with an instrument. Wipe away excess from the cartridge carefully so base and catalyst do not cross contaminate and cause obstruction of the nozzle.\u003c\/li\u003e\n\u003cli\u003eInstall a mixing tip on the cartridge by lining up the notch on the outside rim of the mix tip with the notch on the cartridge flange. If mix tip does not seat easily, be sure the internal end view of the mix tip is aligned correctly. The mix tip itself can turn in its cap.\u003cbr\u003eThe two holes should line up with the piece that is on the outside rim of the mix tip cap to facilitate inserting. Turn tip to align in its cap.\u003c\/li\u003e\n\u003cli\u003eWhen mix tip notch is lined up with the notch on the cartridge flange, turn mix tip cap 90° in a clockwise direction to lock in place on cartridge.\u003c\/li\u003e\n\u003cli\u003eSqueeze dispenser trigger with moderate and even pressure to begin mixing\/dispensing material. Material will stop flowing after trigger is released. Disinfect barrels and used mix tip for storage. Immediately prior to next use, bleed syringe and install new mix tip as outlined above.\u003c\/li\u003e\n\u003cli\u003eTo remove cartridge, push up lever and pull slide flush. Lift plastic lever on the top of gun and remove cartridge.\u003c\/li\u003e\n\u003cli\u003eDispense a small amount through the mix tip onto a mixing pad and discard. Without delay, begin dispensing Integrity Material directly into the preliminary impression into the area of the preparation by applying continuous, light pressure to the dispensing apparatus handle. As the material comes out of the mixing tip, inject it into the deepest portion of the preliminary impression and then into the gingival areas, keeping the mixing tip immersed in the material to prevent bubbles. Reseat the preliminary impression into the patient’s mouth in the proper relative position within 45 seconds of the start of mix.\u003c\/li\u003e\n\u003cli\u003eLeave impression in place for approximately 2-3 minutes from the start of the mix.\u003cbr\u003eRemove the impression containing the Integrity Material restoration during the firm elastic stage.\u003c\/li\u003e\n\u003cli\u003eAt this elastic phase, gross excess may be quickly trimmed with sharp scissors, being careful not to distort the restoration or margins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Dentsply","offers":[{"title":"Default Title","offer_id":67575909646640,"sku":"DentsplyIntegrity","price":148.69,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/2754\/9488\/files\/dentsply-integrity-temporary-crown-and-bridge-material-2_1.webp?v=1787372164","url":"https:\/\/vehca.com\/products\/dentsply-integrity-temporary-crown-and-bridge-material","provider":"VEHCA | AN ONLINE BEAUTY STORE","version":"1.0","type":"link"}