{"product_id":"dentsply-calamus-dual-obturation-system-kit","title":"Dentsply Calamus Dual Obturation System Kit","description":"\u003cp\u003e\u003cspan\u003eCalamus Dual is a kit for three-dimensional\u003c\/span\u003e\u003cspan\u003e obturation\u003c\/span\u003e\u003cspan\u003e of the root canals with vertical condensation and squirt techniques. It is completed with two tips used for condensation (Pack) and filling (Flow) of root canals. The \"+\" and \"-\" keys for ease of operation. Settings can be individually adapted. Clear display and control keys. Save your preferred settings as 2 programs. \u003c\/span\u003e\u003cspan\u003eThe transparent window on the tip shows the content of gutta-percha in the \u003c\/span\u003e\u003cspan\u003eCartridge. Fast\u003c\/span\u003e\u003cspan\u003e and reliable Vertical condensation with a faster method to achieve debt TERM-sealed three-dimensional root canal \u003c\/span\u003e\u003cspan\u003eobturation. Reliable \u003c\/span\u003e\u003cspan\u003eobturation of lateral \u003c\/span\u003e\u003cspan\u003echannels. Root\u003c\/span\u003e\u003cspan\u003e fracture risk is minimized. \u003c\/span\u003e\u003cspan\u003eQuick change of cartridges is achieved due to a simple mechanism of their fixation and removal with minimal cleaning. Flexible and long heat-conducting silver alloy cannulas are also suitable for curved channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eEasy to clean and maintain.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eConvenience and control: The device is designed for your comfort. Convenient operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eTips are ergonomically designed with a large operating angle.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eActivation with a light touch of a flexible silicone ring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eRoot canal mouths are clearly visible thanks to thin tips.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eOptical and sound signals improve workflow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\n\u003cspan\u003ePlugers\u003c\/span\u003e\u003cspan\u003e can be used both for condensation (DownPack) and for cutting gutta-percha. Thermal nozzle for determining the vitality of tooth pulp. BackFill procedure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eHeating temperature and injection rate can be set individually.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli aria-level=\"1\"\u003e\u003cspan\u003eThe micromotor controls the precise supply of gutta-percha.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"sc-892bc00b-0 sc-1d8c424f-0 cymOrW\"\u003e\n\u003cdiv class=\"sc-eb36be54-0 jrfDqn\"\u003e\n\u003cdiv class=\"sc-eb36be54-2 fPHBZi\"\u003e\n\u003cdiv class=\"sc-1d8c424f-1 haNrmt\"\u003e\n\u003cdiv class=\"sc-892bc00b-0 sc-892bc00b-4 sc-1d8c424f-2 cymOrW kwxfio izBlDE [\u0026amp;_ul]:!list-disc\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsole Dimensions:-\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e11.2 x 15.0 x 15.2 cm (4.4” x 5.9” x 6.0”)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e1.6 kg (3.6 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source: \u003c\/strong\u003e115V\/60Hz, 230V\/50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating: \u003c\/strong\u003e115V\/0.6A, 230V\/0.3A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuses: 115V:  \u003c\/strong\u003e.0.6A\/250V Slo-Blo® fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e230V:  \u003c\/strong\u003e0.3A\/250V Slo-Blo® fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlugger: \u003c\/strong\u003eStainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapsule Contents: \u003c\/strong\u003eGutta-Percha\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapsule: \u003c\/strong\u003eAluminium\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCannula : \u003c\/strong\u003eSilver\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e Environmental Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:  \u003c\/strong\u003e10° to 28°C (50° to 82.4°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature: \u003c\/strong\u003e-20 to 60°C (-4° to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity: \u003c\/strong\u003e5 to 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude: \u003c\/strong\u003e0 to 3048 meters (0 to 10,000 feet)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Calamus Dual device\u003c\/li\u003e\n\u003cli\u003e1 x Plugger small ISO 40 - Taper .03\u003c\/li\u003e\n\u003cli\u003ePack of 10 cartridges 20G\u003c\/li\u003e\n\u003cli\u003ePack of 10 cartridges 23G\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDirection To Use: \u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnpacking and Voltage Selection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUnpack the console and ensure that the Voltage Selector is set to the proper voltage according to your electrical supply.\u003c\/li\u003e\n\u003cli\u003eUse the 115V position for 110-120V 60Hz voltages and the 230V position for 220-250V 50Hz voltages.\u003c\/li\u003e\n\u003cli\u003eAlways unplug the unit before changing fuses or adjusting the voltage selector.\u003c\/li\u003e\n\u003cli\u003eTo change the voltage, use a flat head screwdriver to turn the Voltage Selector on the back of the console to the appropriate voltage setting.\u003c\/li\u003e\n\u003cli\u003eIf you need to change the fuse, replace it with the correct one based on the specifications provided. Press the black plastic clip of the fuse compartment, pull out the old fuse, and replace it with a new one that matches the voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHandpiece Preparation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClean the exterior of the handpieces with a soft cloth moistened with mild non-chlorinated detergent or disinfecting solution.\u003c\/li\u003e\n\u003cli\u003eAvoid using disinfecting solutions that contain phenol, anticorrosives, very acidic, or very alkaline solutions. Do not submerge the handpieces in liquid.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnecting Handpieces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe handpiece cables are color-coded and keyed to fit the proper receptacle on the console.\u003c\/li\u003e\n\u003cli\u003eWith the arrow on the connector facing up, gently push the connector into the console receptacle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Cord Connection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAttach the power cord to the back of the console and plug it into a grounded electrical outlet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Shield:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIf included, place the heat shield over the cannula and handpiece to reduce the surface temperature of the Flow handpiece.\u003c\/li\u003e\n\u003cli\u003eSterilize the heat shield before first use and between each patient using a steam autoclave for 15 minutes at 132°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectric Heat Pluggers (EHP):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSterilize the Electric Heat Pluggers using a steam autoclave for 15 minutes at 132°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePack Handpiece:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePush the Electric Heat Plugger (EHP) into the handpiece tip and slowly rotate it until it clicks in with the handpiece tip. Ensure it is fully engaged for desired heat settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Handpiece:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUnscrew and remove the cartridge nut from the handpiece.\u003c\/li\u003e\n\u003cli\u003eTurn the unit 'OFF' before inserting or replacing a cartridge.\u003c\/li\u003e\n\u003cli\u003eInsert a cartridge into the handpiece with the cannula facing outward.\u003c\/li\u003e\n\u003cli\u003eSlip the cartridge nut over the cannula and screw it clockwise lightly, without over-tightening.\u003c\/li\u003e\n\u003cli\u003eEnsure the cartridge is properly seated by pressing the button on the right side of the control panel. The plunger must be in its retracted position to accept the cartridge.\u003c\/li\u003e\n\u003cli\u003ePlace the heat shield over the cannula and handpiece, and adjust the heat shield until the Flow indicator is visible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBending Tool:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse the bending tool to place a smooth radius curve on the cannula, allowing it to extend within 5 mm of the working length of the canal.\u003c\/li\u003e\n\u003cli\u003ePlace the cannula between the two raised bending posts and gently bend it to the desired angle. Avoid using fingers or non-approved devices to curve the cartridge cannula.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Activation and Operation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTurn on the device by pressing the Power On\/Off button located on the front panel.\u003c\/li\u003e\n\u003cli\u003eThe left side of the console keypad controls the Pack handpiece, while the right side controls the Flow handpiece.\u003c\/li\u003e\n\u003cli\u003ePress the handpiece cuff or any button for the Pack or Flow side to activate the respective handpiece.\u003c\/li\u003e\n\u003cli\u003eThe blue LED indicator at the\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Dentsply","offers":[{"title":"Default Title","offer_id":67575909777712,"sku":null,"price":4259.99,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/2754\/9488\/files\/aswdwesrew.webp?v=1787372169","url":"https:\/\/vehca.com\/products\/dentsply-calamus-dual-obturation-system-kit","provider":"VEHCA | AN ONLINE BEAUTY STORE","version":"1.0","type":"link"}